Independent Dual-Target Lateral Flow Strips (JY0208)

Independent Dual-Target Lateral Flow Strips — Cat. No. JY0208 is a lateral flow strips for simultaneous detection of two independent nucleic acid targets with Biotin/FAM and Digoxin labeling.

📄 Download Full IFU (PDF)

Specifications and Storage

ItemDetails
Catalog NumberJY0208
Product NameIndependent Dual-Target Lateral Flow Strips
Operation Time1-2 minutes read time
Storage Conditions4-30°C, dark and dry
Shelf Life12 months

Procedure

1. Take out the corresponding number of test strips according to the number of samples to be tested, and mark them on the absorbent pad (Figure 1). Each test strip can only be used for single detection of a single sample. When the amplification product volume is 50-100 μL, the nucleic acid product can be directly detected in a 200 μL PCR reaction tube. When the product volume is less than 50 μL, ultrapure water needs to be added to the PCR tube to make up the volume to 50 μL, mix thoroughly by pipetting, and then detection can be performed. 2. After PCR, RPA, or RAA reaction is completed, open the PCR reaction tube and insert the conjugate pad end (arrow end) of the test strip into the PCR reaction tube (Figure 1). The liquid level must not exceed the top of the conjugate pad. Wait for the reading zone to be fully wetted (approximately 1-2 minutes; when the ambient temperature is low, such as in winter, the wicking speed will be reduced and the wetting time of the reading zone will be extended). After the control line (C line) develops color, the test strip can be removed. Read the detection result directly according to the color development of the test strip. 3. Observe the results within 10 minutes after the control line (C line) develops color. Reading after 10 minutes is invalid. 4. Record the detection results and seal and discard the test strips in a safe place. Interpretation of Results: Figure 2. Schematic Diagram of Disposable Nucleic Acid Detection Test Strip Result Interpretation 1. Positive (+): The test strip shows one blue band at the control line (C line) and 2 red bands at the test line (T line). A positive result indicates that the sample contains the nucleic acid fragment to be tested, and its quantity is ≥ the minimum detectable limit of the test strip. When the target nucleic acid product concentration is low, the test strip C line appears blue and the T line appears light red or even light pink, and this result should also be judged as positive. When the target nucleic acid product concentration is high, both the C line and T line appear red, and this result should also be judged as positive. 2. Negative (-): A blue band appears at the control line (C line) of the test strip, and no band appears at the test line (T line). A negative result indicates that the sample does not contain the target nucleic acid fragment, or its quantity is below the minimum detectable limit of the test strip. 3. Invalid: No bands appear at both the control line (C line) and the test line (T line) of the test strip, indicating that the test strip or amplification reagent used may be damaged, invalid, or there was an operational error. In this case, read the instructions carefully, re-amplify and re-test. If the problem persists, stop using the product from the same batch immediately and contact the local supplier.

Warnings and Precautions

  1. This product is for research use only. Please read the instructions carefully before use and operate strictly
  2. according to the instructions. Violation or failure to operate according to the instructions may lead to erroneous
  3. The product should be stored under appropriate environmental conditions and temperature according to the
  4. instructions and used within the validity period. Improper storage or expired product may lead to erroneous
  5. results. Use the test strips as soon as possible after opening the package to avoid affecting the test results due to
  6. moisture. Insufficient lighting in the detection environment, operator color weakness, and other factors may lead
  7. to erroneous results.

FAQ: Independent Dual-Target Lateral Flow Strips

What is JY0208 used for?

JY0208 is a lateral flow strips for simultaneous detection of two independent nucleic acid targets with Biotin/FAM and Digoxin labeling. It is designed for rapid sample processing in molecular diagnostics and research applications.

Does Due Bio support OEM/ODM for JY0208?

Yes. Due Bio / TiosBio supports OEM packaging, private-label formulations, bulk supply, and customized documentation for qualified distributors and diagnostic manufacturers. Contact Due Bio with your target market, expected annual volume, and packaging requirements.

Related Technical Guides

This product is supplied for research use only. For OEM/ODM cooperation, distributor quotations, or regulatory documentation requests, contact Due Bio through the Contact page.